1. HOME
  2. Products
  3. TDR (Impedance) Tester
  4. Line Up
  5. TDR4033

TDR4033

TDR4033

Specifications
Axis1 axis2 axis
Max. Test Area [vacuuming area]12.6 x 10.6" (320x270mm)9.6 x 10.6" (230x270mm)
Clamping MethodVacuuming / TDR Multi Clamp
Rotate Radius325° (In case of Single Probe)
235° (In case of Differential Probe set at 90°)
145° (In case of Differential Probe set at 180°)
Repeatable Accuracy X-Y±3µm
Repeatable Accuracy θ
Impedance Accuracy*150Ω±1%
Air RequirementPressure:0.5Mpa, Consumption:11gal/min(42ℓ/min)
Power SupplySingle Phase AC200-240V 5A 50/60Hz
Weight2156lbs. (980kg)2200lbs. (1000Kg)
DimensionsDimensions
*1Calibration allows room temperature variation of ±2°C.
Measurement item
Measurement itemControlled Impedance
Testable TerminalsC4 Bump, Pad for BGA
InterfacesTektronix
Operating condition Operating temperature: 0-+40°C.,
Storing temperature: 0-+50°C.,
No condensation, dust, vibration nor any corrosive gas