1. HOME
  2. Products
  3. Moving Probe Tester
  4. Line Up
  5. FHX6151

F Series

FHX6151

Specifications
Max. Test Area24 x 20" (610x510mm)
Number of Probe2 Upper
Min. Board Size2 x 2" (50x50mm)
Max. Board Thickness for Clamping0.4" (10mm)
Repeatable Accuracy±0.000157" (±4µm)
Resolution0.000079" (2µm)
Min. Pad Pitch *10.001969" (50µm)
Min. Pad Size *20.00039" (10µm)
Test Voltage of Resistance MeasurementContinuity test:0-10V
Isolation test: 250V(500V/1000V option)
Test Current of Resistance MeasurementContinuity test:2.65µA-150mA
Clamp SystemVacuum Style
Number of CCD Camera2 Upper
Monitornot available
Printerexternal
Air RequirementsPressure:0.5MPa, Consumption:1.5gal/min.(5.7ℓ/min.)
Power Supply *38A (Single Phase AC200-240V 50/60Hz)
Weight2640lbs. (1200kg)
DimensionsDimensions
*1When Probe (T96MC-PB-0R40) used.
*2When Probe (T96MC-PB-0B00) used.
*3Breaker specification: Interrupting capacity should be 1.25 times or over the machine current and Instantaneous tripping current shall be 800% or over the machine current.
System Requirements
System RequirementsControl PC & Monitor
Probe TypeUsers can choose one of different types of probes depending on tester models. Please ask our sales for specifications of each probe & PC.
SoftwareEMMA2010 is standard, Ask our sales department about our optional software.
Operating Conditions70-75°F (21-24°C), 30-70% relative humidity
non-condensing, no dust, no vibration, no corrosive gas.