1. HOME
  2. Products
  3. Moving Probe Tester
  4. Line Up
  5. EMX12181/EMX15281

M Series

EMX12181/EMX15281

Specifications(EMX12181/EMX15281)
Max. Test Area47 x 31.5" (1200x800mm) / 59.8 x 31.8" (1520x810mm)
Number of Probe2 Front, 2 Rear
Min. Board Size1.3 x 2.6" (35x65mm)
Max. Board Thickness for Clamping0.511" (13mm)
Repeatable Accuracy±0.000157" (±4µm)
Resolution0.000236" (6µm)
Min. Pad Pitch *10.007087" (180µm)
Min. Pad Size *20.00314" (80µm)
Test Voltage of Resistance MeasurementContinuity test:0-10V
Isolation test: 250V(500V/1000V option)
Test Current of Resistance MeasurementContinuity test:2.65µA-150mA
Clamp SystemPneumatic
Number of CCD Camera2 Front, 2 Rear
Monitornot available
Printerexternal
Air RequirementsPressure:0.5MPa, Consumption:1.5gal/min.(5.7ℓ/min.)
Power Supply *315A (Single Phase AC200-240V 50/60Hz)
Weight3682lbs. (1670kg)
DimensionsDimensions
Dimensions
*1When Probe (T96MC-PB-0R40) used.
*2When Probe (T96MC-PB-0B00) used.
*3Breaker specification: Interrupting capacity should be 1.25 times or over the machine current and Instantaneous tripping current shall be 800% or over the machine current.
System Requirements
System RequirementsControl PC & Monitor
Probe TypeUsers can choose one of different types of probes depending on tester models. Please ask our sales for specifications of each probe & PC.
SoftwareEMMA2010 is standard, Ask our sales department about our optional software.
Operating Conditions70-75°F (21-24°C), 30-70% relative humidity
non-condensing, no dust, no vibration, no corrosive gas.