Specifications(EHX4033/EHX6151)
Max. Test Area15.7 x 13" (400x330mm) / 24 x 20" (610x510mm)
Number of Probe2 Front, 2 Rear
Min. Board Size0.8 x 1.8" (20x45mm)
Max. Board Thickness for Clamping0.354" (9mm)
Repeatable Accuracy±0.000118" (±3µm) / ±0.000157" (±4µm)
Resolution0.000079" (2µm)
Min. Pad Pitch *10.001969" (50µm)
Min. Pad Size *20.00039" (10µm)
Test Voltage of Resistance MeasurementContinuity test:0-10V
Isolation test: 250V(500V/1000V option)
Test Current of Resistance MeasurementContinuity test:2.65µA-150mA
Clamp SystemPneumatic
Number of CCD Camera2 Front, 2 Rear
Monitornot available
Printerexternal
Air RequirementsPressure:0.5MPa, Consumption:1.5gal/min.(5.7ℓ/min.)
Power Supply *310A (Single Phase AC200-240V 50/60Hz)
Weight2800lbs. (1270kg) / 2425lbs. (1100kg)
DimensionsDimensions
*1When Probe (T96MC-PB-0R40) used.
*2When Probe (T96MC-PB-0B00) used.
*3Breaker specification: Interrupting capacity should be 1.25 times or over the machine current and Instantaneous tripping current shall be 800% or over the machine current.
System Requirements
System RequirementsControl PC & Monitor
Probe TypeUsers can choose one of different types of probes depending on tester models. Please ask our sales for specifications of each probe & PC.
SoftwareEMMA2010 is standard, Ask our sales department about our optional software.
Operating Conditions70-75°F (21-24°C), 30-70% relative humidity
non-condensing, no dust, no vibration, no corrosive gas.